Catalog | Video |
Execution standard: GB/T 7551-1997 Certificate (eqv OIML R60) Combined error: 0.015% Sealed to IEC 529: Protection grade: IP67 or IP68. Protection against total immersion in water for 30 minutes at a pressure corresponding to a 1 m head of water. |
|
Dimensions
(In mm. 1mm = 0.03937 inches)
CAP./SIZE |
L |
L1 |
L2 |
L3 |
L4 |
H |
H1 |
H2 |
W |
W1 |
M |
N-D |
R |
1,2,3t |
320 |
230 |
145 |
120 |
275 |
85 |
18 |
25 |
40 |
- |
M12 |
2- Φ18 |
60 |
5,7,10t |
310 |
240 |
145 |
120 |
275 |
100 |
18 |
30 |
50 |
25 |
M12 |
4- Φ13 |
60 |
15,20,30t |
390 |
300 |
210 |
180 |
345 |
127 |
20 |
45 |
56 |
29 |
M16 |
4- Φ18 |
80 |
40,50,60t |
500 |
395 |
235 |
200 |
445 |
173 |
21 |
67 |
86 |
45 |
M20 |
4- Φ22 |
90 |
Circuit Diagram:
Electrical Termination
4 Core cable standard lengths:
1~3t: 3m, 5~10t: 6m, >=20t:10m
Diameter: Φ6
Connection:
Refer to the following drawing:
Notice: Do not change the length of cable, or lese, it will effect the sensitivity of loadcell.
Specification
Item Parameter |
C3 |
Unit |
Rated load (Emax): |
1~60 |
t |
Maximal numbers of load cell verification Intervals (Nlc): |
3000 |
d |
Minimum load cell verification intervals Intervals ( Vmin): |
0.01 |
% of rated load |
Rated output (Cn): |
2.0±0.1% |
mV/V |
Combined error: |
0.015 |
-% of rated output |
Temperature effect on sensitivity(Tkc): |
0.0012 |
=% of rated output/ |
Temperature effect on zero balance(Tk0): |
0.0008 |
-% of rated output |
Zero balance: |
1.0 |
-% of rated output |
Input resistance(Rlc): |
775±5 |
Ω(Ohms) |
Output resistance(Ro): |
702±2 |
Ω(Ohms) |
Insulation resistance: |
≥5000 |
MΩ (Mega-Ohms) |
Safe overload: |
150 |
% of rated capability |
Ultimate overload: |
300 |
% of rated capability |
Operating temperature range: |
-20~+70/-20~+160 |
℃/ °F |
Recommend excitation: |
8~15 |
V( DC or AC) |
Maximum excitation: |
24 |
V( DC or AC) |
Material of elastomer: |
Alloy steel / Stainless steel |
|
Protection class: |
IP67/IP68 |
Hotline.
Ms. Vân Anh - 0904883101